Capacity 20 – 25 – 30 – 40 – 50 t
3000 divisions OIML-R60 Measuring element from steel alloy Protected against corrosion by nickel-plated treatment Protected against humidity IP-67 With gas dischargers to protect against atmospheric discharges Avalable in ATEX version (optional) [II 1GD Ex ia IIC T4...T6 Ga] [II 1GD Ex ia IIIC T135ºC Da]
Technical data | Accuracy class | C3-C4 | | Rated output | 2 ± 0.1% mV/V | | Vmin | Emax/10000 | | Excitation Voltage | 5÷15V | | Input Resistance | 700 ± 3Ω | | Output Resistance | 700 ± 3Ω | | Temperature Compensation | -10ºC/+40ºC | | Temperature limits | -30ºC/ +70ºC | | Insulation resistance | > 5000 MΩ |
 |